⚡ Dual Standard NEC AWG + IEC mm² • Auto Breaker (Ib ≤ In ≤ Iz)

Wire Size & Voltage Drop Calc

Stop testing wire gauges one by one! Automatically calculates commercial AWG & metric mm² sizes, breaker trip ratings (Ib ≤ In ≤ Iz), 8 conductor metals (Copper, Aluminum, Pure Nickel, Nichrome), AC Mains, 12V/24V/48V Solar, 40% Conduit Fill, and 40 Offline Guides.

🔥 LAUNCH EDITION (v1.0) — EARLY ADOPTER ACCESS: Download free on Android right now and lock in full access to all core calculators & 40 offline guides before our upcoming Pro subscription update!
📲 Download Free on Google Play (v1.0)

✓ Free on Android • ✓ 100% Offline • ✓ Verified Calculations

⚡ Live Interactive Mini-Calculator: Voltage Drop & Joule Heat

Ohm's Law Engine

Test conductor resistance (R = ρ·L/A) and see heat wasted in the cable before installation:




Voltage Drop on 4 mm² (12 AWG): 7.88V (3.43%) — ⚠️ EXCEEDS 3% LIMIT!
Joule Heat Loss in Cable: 157.5 Watts
💡 Need auto AWG/mm² sizing, 8 conductor metals & breaker trip math? Unlock Android Toolkit →

Latest Field Guides & Technical Manuals

Why Residential AC Breakers Catch Fire on DC Solar Panels (Zero-Crossing Physics)
Published 2026-11-13 • Editorial Field Guide

Why Residential AC Breakers Catch Fire on DC Solar Panels (Zero-Crossing Physics)

Never wire standard household AC circuit breakers into off-grid solar PV strings or 48V LiFePO4 battery banks. Understand DC arc plasma sustainment, polarity traps, and NEC DC-rated disconnects.

Read Full Guide & Calculator →
Pure Nickel vs. Nickel-Plated Steel: Sizing Strips for 18650 & LiFePO4 DIY Battery Packs
Published 2026-11-10 • Editorial Field Guide

Pure Nickel vs. Nickel-Plated Steel: Sizing Strips for 18650 & LiFePO4 DIY Battery Packs

Spot-welding DIY 18650 or LiFePO4 lithium battery packs? Discover why cheap nickel-plated steel strips overheat, how to test for 99.6% pure nickel, and how to calculate ampacity and heat loss.

Read Full Guide & Calculator →
NEC (AWG) vs. IEC (mm²) Wire Sizing & Why Breakers Must Obey Ib ≤ In ≤ Iz
Published 2026-11-10 • Editorial Field Guide

NEC (AWG) vs. IEC (mm²) Wire Sizing & Why Breakers Must Obey Ib ≤ In ≤ Iz

Discover why cables melt even when the circuit breaker doesn't trip, how long wire runs create hidden I²R heat losses, and how to size both American AWG and commercial Metric mm² conductors in one tap.

Read Full Guide & Calculator →
The 40% Conduit Fill Rule: How to Size PVC, EMT & Flexible Conduit Without Jamming Wires
Published 2026-11-10 • Editorial Field Guide

The 40% Conduit Fill Rule: How to Size PVC, EMT & Flexible Conduit Without Jamming Wires

Master the 40% conduit fill rule for PVC, EMT, and flexible corrugated conduit. Learn why overcrowding wires causes thermal derating, cable damage, and code inspection failures.

Read Full Guide & Calculator →
12V vs. 24V vs. 48V Solar Battery Wiring: How to Size Inverter Cables & Class-T Fuses Safely
Published 2026-11-10 • Editorial Field Guide

12V vs. 24V vs. 48V Solar Battery Wiring: How to Size Inverter Cables & Class-T Fuses Safely

Why a 3000W inverter on a 12V battery bank demands massive 4/0 AWG copper cables, how switching to 48V saves hundreds of dollars in copper, and how to pick the exact ANL, MEGA, or Class-T DC fuse.

Read Full Guide & Calculator →